GPI/Tallies
Press Insert Event > More > More > GPO/Tally.
Command | Description |
---|---|
Panel Tallies | Manually opens or closes the selected panel tally.
|
Frame Tallies | Manually opens or closes the selected frame tally.
|
Contact Closure | Manually opens or closes the selected contact closure.
|
GPO Reset | Returns the GPI output signal to the base level. For a level high GPI (5V) reset sets the GPI to low (0V), and for a level low GPI (0V)
reset sets the GPI to high (5V). Reset GPI does not apply to pulse GPIs.
|
GPO Simulate | Manually trigger a GPI input on the switcher. The switcher reacts as if a trigger was received on the selected input GPI. Simulate
applies to both level and pulse GPIs.
|
GPO Toggle | Toggles the GPI output signal to the opposite level. If the level GPI is currently set to high (5V), toggle sets the GPI to low (0V).
Toggle always sets the level to the opposite of what it currently is, regardless of the trigger level. Toggle GPI does not apply to pulse GPIs.
|
GPO Trigger | Sets the GPI output to the trigger level. For a level high GPI (5V) trigger sets the GPI to high (5V), even if the GPI is already
triggered and at high (5V). Trigger applies to both level and pulse GPIs.
|