Video Reference and Operating Format

AirCleaner-2 accepts either Bi-Level or Tri-Level analog reference and can be gen-locked to these reference signals only when the frame rate of the reference signal matches the frame rate of the video input and output.

The reference signal will lock both the PGM OUT and TAP OUT together in time with the reference signal. The reference input is non-terminating with loop-though.

Reference can also be set to lock to the PGM IN or AUX IN video signal or set to free run.

The input video signal must be at the same frame-rate as the input reference signal.