SSL®

This setup information applies to the C10 HD and System T S300, S500, and TCR.

Cable Connections

The C10 HD connects to the switcher over an RS-422 serial connection to a DB9 port on the switcher and a DB9 port on the device.

The System T consoles connect to the switcher over standard ethernet.

Table 1. Switcher to C10 HD Cable Connections
Acuity (Remote Port) C10 HD (RS422 Port)
2 (Rx-) 2 (Tx-)
3 (Tx+) 3 (Rx+)
7 (Rx+) 7 (Tx+)
8 (Tx-) 8 (Rx-)

Switcher Setup

The switcher must be set up to communicate with the audio mixer using either serial or ethernet protocols, as well as associate the audio channels on the mixer with video sources coming into the switcher.

To Set Up Serial Communications

This information applies to the C10 HD.

  1. Press HOME > Setup > Installation > Com Setup
  2. Press Type and use the Com Port knob to select the remote port that you want to set up for the device.
  3. Use the Device knob to select Audio Mixer.
  4. Press Select Device and use the Device knob to select RAP.
  5. Press Com Type and use the Type knob to select RS-422.
  6. Press Com Settings and use the Baud and Parity knobs to select 115200 (Baud) and ODD (Parity).
  7. Press Extra Options and use the Option and Value knobs to set the device parameters.
    Option Value
    TargetMachine Generic
    Ctrl Master M1 (default)
    Multiplier 2 (default)
  8. Press HOME > Confirm.

To Set Up Ethernet Communications

This information applies to the S300, S500, and TCR.

  1. Press HOME > Setup > Installation > Com Setup
  2. Press Type and use the Com Port knob to select the remote port that you want to set up for the device.
  3. Use the Device knob to select Audio Mixer.
  4. Press Select Device and use the Device knob to select RAP.
  5. Press Com Type and use the Type knob to select Network TCP.
  6. Press Com Settings and use the Client/Server knob to select Client and enter the IP Settings.
    IP Setting Value
    Remote IP Address (IP of device)
    Remote Port 10001
    Local IP Address 0.0.0.0
    Local Port 0
  7. Press Extra Options and use the Option and Value knobs to set the device parameters.
    Option Value
    TargetMachine Generic
    Ctrl Master S1
    Multiplier 2 (default)
  8. Press HOME > Confirm.

To Set Up a Video Input

Tip: Refer to your switcher Setup manual for information on setting up audio groups.
  1. Press HOME > Setup > Installation > Source Configuration > Audio.
  2. Use the Input knob to select the input source that you want to assign an audio channel or group to.
  3. Use the Audio X knob to select the audio channel, or group, that you want to assign to the selected source. You can assign up to two channels or groups.
  4. Press HOME > Confirm.

Device Setup

The device must be set up to communicate with the switcher using the same serial or ethernet communications as you set the switcher up to use.

Note: This information in this procedure is provided as a guide and is based on the current version of hardware and software that was available at the time of testing. For the most accurate and up-to-date information, refer to the documentation that came with your device.

To Set Up Serial Communication

You must enable REMOTE ON in the C10 HD console, via the soft-key.