Ross® PIVOTCam

The information in this document applies to the PIVOTCam-20 and PIVOTCam-SE.

Note: The PIVOTCam-SE must be running firmware version 2.0C, including ARM 2.1A and ISP 263.

Cable Connections

Cable connections to the PIVOTCam depend on the model of PIVOTCam you have.

PIVOTCam-20

To control the camera from the switcher and/or DashBoard you must connect a serial cable to the 8-Pin Mini-DIN RS232 IN port on the camera to a Serial to Ethernet converter (such as the Moxa Nport® 5150A available from Ross®) and then an ethernet connection from the Nport® 5150A to the switcher and/or DashBoard.

The Moxa Nport® 5150A is a serial to ethernet converter that allows DashBoard and the switcher to connect to a serial device over ethernet, but any serial to ethernet converter device can be used.

Note: You can control the camera directly using an RS-232 connection from the control panel to the camera.

PIVOTCam-SE

To control the PIVOTCam-SE from the switcher and/or DashBoard you must connect an ethernet cable to the LAN port on the camera that is connected to the same subnet as the switcher and/or DashBoard. You must connect on port 52381 for direct control from the switcher.

Note: The camera accepts PoE (Power over Ethernet) and can be powered either by the ethernet connection or the mains power connection. Both can be connected at the same time.
Tip: In DashBoard 8.7, or higher, you can use the DashBoard interface to a VISCA camera as a gateway to allow the switcher to control the camera through DashBoard.
Tip: You can also cable the PIVOTCam-SE the same as the PIVOTCam-20 using an 8-Pin Mini-DIN RS232 IN to a Serial to Ethernet converter (such as the Moxa Nport® 5150A).

PIVOTCam-20 to Nport® 5150A Cabling

A serial cable (RS-232 Control Cable provided with camera) is used to connect the PIVOTCam-20 to the Nport® 5150A. A standard ethernet connection is used between the Nport® 5150A and the switcher.

Table 1. PIVOTCam-20 to Nport® 5150A
PIVOTCam-20 (RS232 IN) Nport® 5150A (Port 1)
3 (Tx) 2 (Rx)
5 (Rx) 3 (Tx)
4 (GND) 5 (GND)

Switcher Communication Setup

The switcher must be set up to communicate with the robotic camera using specific protocol settings.

To Set Up Ethernet Communications

  1. Press HOME > Setup > Installation > Com Setup
  2. Press Type and use the Com Port knob to select the net port that you want to set up for the device.
  3. Use the Device knob to select Robotic Cam.
  4. Press Select Device and use the Device knob to select VISCA.
  5. Press Com Type and use the Type knob to select Network TCP.
  6. Press Com Settings and use the Client/Server knob to select Client and enter the IP Settings.
    IP Setting Value
    Remote IP Address
    • PIVOTCam-20 (IP of Nport® 5150A)
    • PIVOTCam-SE Direct (IP of camera)
    • PIVOTCam-SE DashBoard Gateway (IP of DashBoard computer)
    Remote Port
    • PIVOTCam-20: 52381
    • PIVOTCam-SE Direct: 52381
    • PIVOTCam-SE DashBoard Gateway: (the port assigned to the camera in the VISCA Gateway on DashBoard)
    Local IP Address 0.0.0.0
    Local Port
    • PIVOTCam-20: 52381
    • PIVOTCam-SE Direct: 52381
    • PIVOTCam-SE DashBoard Gateway: (the port assigned to the camera in the VISCA Gateway on DashBoard)
  7. Press Extra Options and use the Option and Value knobs to set the device parameters.
    Option Value
    Pan Speed 24 (default)
    Tilt Speed 20 (default)
    Model Ross PIVOTCam
    Protocol Serial
    Tally No (default)
  8. Press HOME > Confirm.

Switcher Video Setup

The switcher must be set up to associate the camera controls with the video source coming into the switcher. When you select the source coming from the camera on a bus, the menu jumps to the camera controls for that camera.

To Set Up a Video Input

  1. Press HOME > Setup > Installation > Source Configuration > Input Type.
  2. Use the Input knob to select the input source that is coming from the camera.
  3. In the Input Type area, select Robotic Camera.
  4. Press More.
  5. Press Camera Setup and use the Controller knob to select the camera that the video source is coming from.
  6. Use the Port knob to select the port on the camera controller that you are connecting to.
  7. Press Camera Options and use the Option and Value to set the camera parameters.
    Option Value
    Pan Invert Invert the direction that the camera moves when using the positioner (Yes), or not (No).
    Tilt Invert Invert the direction that the camera moves when using the positioner (Yes), or not (No).
    Zoom Invert Invert the direction that the camera zooms when using the positioner (Yes), or not (No).
    Focus Invert Invert the focus direction when using the positioner (Yes), or not (No).
    Iris Invert Invert the iris direction when using the positioner (Yes), or not (No).
    X Invert Invert the direction that the camera moves in the X-axis when using the positioner (Yes), or not (No).
    Y Invert Invert the direction that the camera moves in the Y-axis when using the positioner (Yes), or not (No).
    Z Invert Invert the direction that the camera moves in the Z-axis when using the positioner (Yes), or not (No).
  8. Press More.
  9. Press Channel Name and enter a new name for the camera and press Accept New Name.

    This allows you to override the mnemonic name of the camera source with a name that is specific to the camera.

  10. Press HOME > Confirm.

Nport® 5150A Setup

Note: This information in this procedure is provided as a guide and is based on the current version of hardware and software that was available at the time of testing. For the most accurate and up-to-date information, refer to the documentation that came with your device.

Refer to the documentation that came with your Nport® 5150A for safety and setup information.

Use the NPort Administrator application to set up the Nport® 5150A as listed below.

Operation Mode

  • Operation Mode — TCP Server Mode
  • Max Connection — 2 (or more)

Serial Parameters

  • Baud rate — 9600
  • Data bits — 8
  • Stop bits — 1
  • Parity — None
  • Flow control — RTS/CTS
  • FIFO — Enable
  • Interface — RS-232

Ethernet Parameters

  • IP Address — the default IP address is shown on the bottom of the device
  • Local TCP Port — 4001 (default)

Robotic Camera Setup

Note: This information in this procedure is provided as a guide and is based on the current version of hardware and software that was available at the time of testing. For the most accurate and up-to-date information, refer to the documentation that came with your device.

PIVOTCam-20

On the PIVOTCam-20, the following changes must be made on the SYSTEM menu:

  • PROTOCOL — set to VISCA
  • RS485 — set to OFF
  • BAUD RATE — set to 9600

PIVOTCam-SE

Tip: If you are controlling the PIVOTCam-SE over a serial connection, use the setup information for the PIVOTCam-20 and set VISCA to OVER COM.

On the PIVOTCam-SE, the following changes must be made on the SYSTEM menu:

  • PROTOCOL — set to VISCA
  • VISCA — set to OVER IP for ethernet control

Daisy Chaining

If you are daisy chaining multiple PIVOTCam cameras together, use the following pinouts to connect the one camera to the next.

Table 2. Camera to Camera Cable Connections
RS232 Out RS232 In
1 (DTR) 2 (DSR)
2 (DSR) 1 (DTR)
3 (Tx) 5 (Rx)
4 (Gnd) 4 (Gnd)
5 (Rx) 3 (Tx)

DashBoard Gateway Setup

Note: This information in this procedure is provided as a guide and is based on the current version of hardware and software that was available at the time of testing. For the most accurate and up-to-date information, refer to the documentation that came with your device.

Before setting up the gateway, you must set up control of the VISCA camera in DashBoard. Refer to the DashBoard documentation for information on controlling a camera from DashBoard.

  1. On the camera tab in DashBoard, click Config > Gateway.
  2. In the Port field, enter the port number you want to use to control the camera from the switcher. This is the port number that you will enter in the device setup on the switcher.
    Note: Each camera controlled by the same DashBoard application must be assigned to a different port.
  3. Select what control you want the gateway to pass on to the camera from the switcher.
    • Focus Mode — select whether the gateway passes focus mode selections made from the switcher on to the camera (Pass), or if the gateway blocks these messages (Block). An external controller can still read the current focus mode when set to Block.
      Tip: The switcher automatically sets and updates the focus mode when controlling the camera. This can prevent other controllers from changing the focus mode when the switcher is controlling the camera and the Focus Mode is set to Pass.
    • Presets — select whether the gateway stores camera shots on the camera (Camera), or on the DashBoard computer (Local).
      Tip: Presets are available through DashBoard whether they are stored on the DashBoard computer or on the camera.
  4. Click a Control button to allow the switcher to use the gateway to control the camera (Enable) or block the switcher from controlling the camera through the gateway (Disable).
  5. On the camera tab, click Config > Operation.
  6. Select how you want use the presets.
    • Manage Presets on Camera — select whether presets are stored on the camera as well as in DashBoard. Presets are always available in DashBoard.
    • Recall Presets from — select whether a recall uses the preset saved in DashBoard or on the camera. Presets must have been stored to the camera to be able to recall them from the camera.

The Status field shows the current state of the gateway.

  • Closed — the port is closed or DashBoard isn't connect to the camera.
  • Ready — the port is open, but there are no controllers currently connected to it.
  • Connected — the port is open and one or more controllers are connected to it.
  • Error — an error has occurred. The port may be used by a different service or is being used by a different gateway.