Eagle
This setup information applies to the Eagle Pan Tilt PT-101.
Cable Connections
The device connects to the switcher over an RS-232 serial connection to a DB9 port on the switcher and a port on the device.
Note: If you are connecting to the PT-101 through a PT Controller, an RS-232 to RS-485 converter
may be required. Please contact Ross Video Technical Support for more information on setting up the camera in this
configuration.
Acuity™ (Remote Port) | PT-101 (Connector Block) |
---|---|
2 (Tx) | 2 (Rx) |
3 (Rx) | 3 (Tx) |
5 (GND) | 5 (GND) |
Switcher Setup
The switcher must be set up to communicate with the robotic camera using either serial or ethernet protocols, as well as associate the video inputs that are coming into the switcher from the camera with the specific robotic camera they are coming from.
To Set Up Communications
- Press HOME > Setup > Installation > Com Setup
- Press Type and use the Com Port knob to select the remote port that you want to set up for the device.
- Use the Device knob to select Robotic Cam.
- Press Select Device and use the Device knob to select Eagle.
- Press Com Type and use the Type knob to select RS-232.
- Press Com Settings and use the Baud and Parity knobs to select 9600 (Baud) and NONE (Parity).
-
Press Extra Options and use the Option and Value knobs to set the device
parameters.
Option Value Lens Type Rainbow (default) Master Ped Yes (default) - Press HOME > Confirm.
To Set Up a Video Input
- Press HOME > Setup > Installation > Source Configuration > Input Type.
- Use the Input knob to select the input source that is coming from the camera.
- In the Input Type area, select Robotic Camera.
- Press More.
- Press Camera Setup and use the Controller knob to select the camera that the video source is coming from.
- Use the Port knob to select the port on the camera controller that you are connecting to.
-
Press Camera Options and use the Option and Value to
set the camera parameters.
Option Value Pan Invert Invert the direction that the camera moves when using the positioner (Yes), or not (No). Tilt Invert Invert the direction that the camera moves when using the positioner (Yes), or not (No). Zoom Invert Invert the direction that the camera zooms when using the positioner (Yes), or not (No). Focus Invert Invert the focus direction when using the positioner (Yes), or not (No). Iris Invert Invert the iris direction when using the positioner (Yes), or not (No). X Invert Invert the direction that the camera moves in the X-axis when using the positioner (Yes), or not (No). Y Invert Invert the direction that the camera moves in the Y-axis when using the positioner (Yes), or not (No). Z Invert Invert the direction that the camera moves in the Z-axis when using the positioner (Yes), or not (No). - Press More.
-
Press Channel Name and enter a new name for the camera and press Accept New
Name.
This allows you to override the mnemonic name of the camera source with a name that is specific to the camera.
- Press HOME > Confirm.