Re-entry Depth

Allows you to have the switcher either prevent or allow re-entry chains of more than 4 MEs. For example, ME 1 -> ME 2 -> ME 3 -> ME 4.

Press HOME > Setup > Personality and use the Option knob to select Re-entry Depth.

Note: Re-entry chains of more than 4 MEs can cause line drops.
  • Prevent — can only create re-entry chains up to 4 MEs deep.
  • Warn — can create re-entry chains over 4 MEs deep, but a pop-up is displayed.
  • Allow — can create re-entry chains over 4 MEs deep.