To Set the Switcher Network Settings
-
Open a web browser and navigate to the IP address of the switcher frame. You are prompted to enter a user name and password. The defaults are user and
password.
Note: This is the IP address of the switcher, not the Ultrix™.Tip: If you do not know the IP address of the switcher, you can find it in DashBoard (Devices > Controllers/Matrices > Ultrix) on the image of the Acuity CPU.
-
Click Other... > Network.
This page allows you to change the network configuration of the network ports, as well as enter the current IP Address of the main panel, and satellite panels.
-
In the LAN1 section, enter the IP Address and Subnet Mask for the switcher.
This is the IP address that you will connect to from the control panel(s).
Note: You cannot set the switcher to an IP Address in the range of 192.168.12.xx. This is used internally and will cause interference. The Subnet Mask should be set to 255.255.255.0.Note: The LAN2 port is used internally for connecting to the Ultrix™. These setting cannot be changed. - Optional: Enter the Default Gateway for the frame.
- In the Panel section, enter the IP address of the main panel in the IP Address Main Panel field.
-
Click Change and Reboot.