To Set Up a CCU Joystick Control
- Press HOME > Setup > Installation > Aux Bus > Remote Panels > Remote GPI Assignment.
 - Use the Remote knob to select the auxiliary control panel GPI input that you want to assign an aux bus to.
 - Use the Aux Bus knob to select aux bus that you want to assign to the selected GPI.
 - Use the Source knob to select the video source that you want to be selected on the aux bus when the GPI is triggered.
 - Press Remote GPI Type.
 - Use the Remote knob to select the auxiliary control panel GPI input that you want to set the trigger type for.
 - 
            Use the Type knob to select the type of trigger signal that you want to use.
            
- Low-Override — set the trigger as a temporary override when the circuit is closed (high to low signal). When the circuit opens again (low to high signal), the aux bus output returns to the selected video signal.
 - Low-Toggle — set the trigger as a toggle when the circuit closes (high to low signal). Every time the circuit closes, the override state will toggle.
 - High-Toggle — set the trigger as a toggle when the circuit opens (low to high signal). Every time the circuit opens, the override state will toggle.
 - Latch — set the trigger to latch when the circuit opens or closes. Once latched, the trigger cannot be released except by selecting a different source on the Auxiliary Panel itself.
 - Off — disable GPI trigger.
 
 - Press HOME > Confirm.
 
