To Set Up a CCU Joystick Control
- Press HOME > Setup > Installation > Aux Bus > Remote Panels > Remote GPI Assignment.
- Use the Remote knob to select the auxiliary control panel GPI input that you want to assign an aux bus to.
- Use the Aux Bus knob to select aux bus that you want to assign to the selected GPI.
- Use the Source knob to select the video source that you want to be selected on the aux bus when the GPI is triggered.
- Press Remote GPI Type.
- Use the Remote knob to select the auxiliary control panel GPI input that you want to set the trigger type for.
-
Use the Type knob to select the type of trigger signal that you want to use.
- Low-Override — set the trigger as a temporary override when the circuit is closed (high to low signal). When the circuit opens again (low to high signal), the aux bus output returns to the selected video signal.
- Low-Toggle — set the trigger as a toggle when the circuit closes (high to low signal). Every time the circuit closes, the override state will toggle.
- High-Toggle — set the trigger as a toggle when the circuit opens (low to high signal). Every time the circuit opens, the override state will toggle.
- Latch — set the trigger to latch when the circuit opens or closes. Once latched, the trigger cannot be released except by selecting a different source on the Auxiliary Panel itself.
- Off — disable GPI trigger.
- Press HOME > Confirm.