To Install a Module

Warning Hazardous Voltages: Hazardous voltages are present in this device as long as any of the power supplies are connected to the AC power.
ESD Susceptibility: Static discharge can cause serious damage to sensitive semiconductor devices. Avoid handling the switcher circuit boards in high static environments such as carpeted areas and when synthetic fiber clothing is worn. Touch the frame to dissipate static charge before removing boards from the frame and exercise proper grounding precautions when working on circuit boards.
  1. Lift up the control panel lid and turn off all power supplies in the control panel.
  2. Disconnect the power supplies from mains power.
  3. Install the module into the control panel.
  4. Use a 1/4 inch hex driver to install the four Retaining Nuts located at each corner of the module.
    Figure 1. Install Module
  5. Connect the cables to the module.
    Figure 2. Module Cables
    1. Connect the 4-conductor Module Power Cable to the module.
      This cable delivers power to all of the modules in the row. When connecting the cable, ensure that you do not accidentally unplug it from any neighbouring modules.
    2. Connect both of the CAT5 Module Control Link Cables to the module.
      This cable delivers all of the command signals to and from the module, as well as other modules in the same row.