Tally Ports
There are tally ports on the control panel and the frame. The tally ports 1 and 2 on the control panel and the frame have the same pinouts. On the frame, the tally ports are identified by the slot and the port number.
The tally ports use a female DB25 connector.
Specification | Value |
---|---|
Type | Solid-State Contact Closure |
Input Voltage | 100VDC |
Maximum Current | 120mA |
Note: Tally ports 3 through 6 on the control panel are used for the extended tallies option and require the extended tallies hardware to be installed before they can be used.
Pin | Port 1 | Port 2 | Port 3 | Port 4 | Port 5 | Port 6 |
---|---|---|---|---|---|---|
1 | 1 | 19 | 37 | 55 | 73 | 91 |
2 | 3 | 21 | 39 | 57 | 75 | 93 |
3 | 5 | 23 | 41 | 59 | 77 | 95 |
4 | 7 | 25 | 43 | 61 | 79 | 97 |
5 | 9 | 27 | 45 | 63 | 81 | 99 |
6 | 11 | 29 | 47 | 65 | 83 | 101 |
7 | 13 | 31 | 49 | 67 | 85 | 103 |
8 | 15 | 33 | 51 | 69 | 87 | 105 |
9 | 17 | 35 | 53 | 71 | 89 | 107 |
10 | Common | |||||
11 | Common | |||||
12 | Common | |||||
13 | Common | |||||
14 | 2 | 20 | 38 | 56 | 74 | 92 |
15 | 4 | 22 | 40 | 58 | 76 | 94 |
16 | 6 | 24 | 42 | 60 | 78 | 96 |
17 | 8 | 26 | 44 | 62 | 80 | 98 |
18 | 10 | 28 | 46 | 64 | 82 | 100 |
19 | 12 | 30 | 48 | 66 | 84 | 102 |
20 | 14 | 32 | 50 | 68 | 86 | 104 |
21 | 16 | 34 | 52 | 70 | 88 | 106 |
22 | 18 | 36 | 54 | 72 | 90 | 108 |
23 | Common | |||||
24 | Common | |||||
25 | Common |