Imagine Communications™
This setup information applies to the EDGE Protocol Translator and VIA32 (256×256 or Smaller).
Cable Connections
The device connects to the switcher over an RS-422 serial connection to a DB9 port on the switcher and a DB9 port on the device.
Acuity™ (Remote Port) | EDGE / VIA32 (SERIAL Port) |
---|---|
2 (Rx-) | 2 (Tx-) |
3 (Tx+) | 3 (Rx+) |
7 (Rx+) | 7 (Tx+) |
8 (Tx-) | 8 (Rx-) |
Switcher Setup
The switcher must be set up to communicate with the router, as well as associate the video inputs that are coming into the switcher from the router with the specific router they are coming from.
To Set Up Communications
- Press HOME > Setup > Installation > Com Setup
- Press Type and use the Com Port knob to select the remote port that you want to set up for the device.
- Use the Device knob to select Router.
-
Press Select Device and use the Device knob to select your device.
- EDGE — select GVG NP
- VIA32 — select Via32.
- Press Com Type and use the Type knob to select RS-422.
- Press Com Settings and use the Baud and Parity knobs to select 38400 (Baud) and NONE (Parity).
-
Press Extra Options and use the Option and Value knobs to set the device
parameters.
Option Value Src Xpts (VIA32 only) 32 (default) Dest Xpts (VIA32 only) 32 (default) - Press HOME > Confirm.
To Set Up a Video Input
- Press HOME > Setup > Installation > Source Configuration > Input Type.
- Use the Input knob to select the input source that is coming from the router.
- In the Input Type area, select Router.
- Press More.
- Press Router Setup and use the Router knob to select the router that the video source is coming from.
- Use the BNC DST knob to select the destination, or output, on the router that is feeding the selected input BNC.
- Press Router Options and use the Level knob to select the level, or breakaway, that is switched on the router when a new input is selected.
- Use the Show Mnemonics knob to select whether the router source name is shown on the mnemonic for the selected input (Yes) or if the switcher source name is shown (No).
- Press HOME > Confirm.
Device Setup
The device must be set up to communicate with the switcher using the same serial or ethernet communications as you set the switcher up to use.
To Set Up Serial Communication for the EDGE
On the EDGE Protocol Translator, you must set up the SERIAL 1 or SERIAL 2 port for your router.
To Set Up Serial Communication for the VIA32
- On the VIA32, you must set DIP switch SW2 on the front of the device to allow it to properly connect to the switcher using RS-422.
- The VIA32 must be equipped with the optional internal serial transmit/receive hardware to allow RS-422 communication.
Router Mnemonic Names
If your router/protocol does not support passing mnemonic names to the switcher, you can manually add those names. Refer to Router Mnemonic Names for more information.