To Load a Set

Switcher Sets can only be loaded from the hard drive.

Note: If you are updating an older setup file, you must perform a Recall All followed by a Store All. This updates the setup files the latest format. You can then make changes and store to individual registers if needed.
  1. Click Navigation Menu > Configuration > System > Load Sets.
    Tip: Click Refresh Sets to update the list of available sets.


  2. Click an Available Set button to select the set you want to load the switcher register from. If there is only one set stored then these buttons will not be present.
  3. Click a Load button to load that register. Only those registers that are present in the set are shown.
    • All — recall all registers from the set.
    • Memories — recall only the memory registers from the set.
    • Customs — recall only the custom control registers from the set.
    • Sequences — recall only the Sequencer registers from the set.
    • Installation — recall only the installation registers from the set.
    • Personality — recall only the personality registers from the set.
  4. Click Yes.