To Set the LiveEDL Behavior
Important: A control panel is required to perform this procedure. If you do not have access to a physical control panel, the SoftPanel can be used. The position of items on the menus on the SoftPanel may not match those of a physical panel.
- Press MENU > System > NEXT > NEXT > NEXT > LivEDL Config.
-
Use the GPO knob to select the GPI output that is connected to your video server.
The GPI must be configured as a GPI output before it can be selected.
-
Use the Triggr knob to select when the GPI output is triggered.
- Off — GPI is not triggered
- Start — GPI output is triggered at the beginning of the EDL capture
- Stop — GPI output is triggered at the end of the EDL capture
- Both — GPI output is triggered at the beginning and end of the EDL capture
If Start or Both is selected, you must set the pre-delay for the GPI. - Use the PreDly knob to select the pre-delay interval (in frames) that the switcher waits after the GPI output is triggered before starting to capture EDL data.