Daktronics®
This setup information applies to the Daktronics® Venus®
Daktronics® and Venus® are trademarks of Daktronics, Inc.
Cable Connections
The Daktronics® Venus® connects to the switcher over standard ethernet.
Switcher Setup
The switcher must be set up to communicate with the scoreboard controller using either serial or ethernet protocols.
To Set Up Communications
- Press HOME > Setup > Installation > Com Setup
- Press Type and use the Com Port knob to select the net port that you want to set up for the device.
- Use the Device knob to select VTR (CLIP).
- Press Select Device and use the Device knob to select VDCP.
- Use the Device Preroll knob to select 0.
- Press Com Type and use the Type knob to select Network TCP.
-
Press Com Settings and use the Client/Server knob to select Client and enter the IP
Settings.
IP Setting Value Remote IP Address (IP of device) Remote Port 10000 Local IP Address 0.0.0.0 Local Port 0 -
Press Extra Options and use the Option and Value knobs to set the device
parameters.
Option Value TargetMachine Dak Venus7000 MediaIDLength Long IDs Timeout (fields) 20 Send Tries 5 Cmd Queuing Strict Record Time 60 Playback Mode PB Port Cmds Yes ExtendedChar No LoopRecueTime 13 (default) Clip List Floating List (default) LoopMinLength 7 (default) Play w/Alpha No (default) Cue & Pause No (default) Eject Clip No (default) StatusInterval 5 (default) Status Tries 30 (default) Preroll 0 (default) Panel Master Panel (default) - Press HOME > Confirm.