PBus II Protocol
Cable Connections
The device connects to the switcher over an RS-232 or RS-422 serial connection to a DB9 port on the switcher.
Remote Port (RS-232) | Remote Port (RS-422) |
---|---|
2 (Tx) | 2 (Rx-) |
3 (Rx) | 3 (Tx+) |
5 (GND) | 7 (Rx+) |
8 (Tx-) |
Switcher Setup
The switcher must be set up to communicate with the PBus II device using a serial protocol.
To Set Up Communications
- Press HOME > Setup > Installation > Com Setup
- Press Type and use the Com Port knob to select the remote port that you want to set up for the device.
- Use the Device knob to select Pbus.
- Press Select Device and use the Device knob to select Pbus.
- Press Com Type and use the Type knob to select the transmission standard for your device.
- Press Com Settings and use the Baud and Parity knobs to select the communications setting for your device.
-
Press Extra Options and use the Option and Value knobs to set the device
parameters.
Option Value Query Cmd Relaxed (default) - Press HOME > Confirm.