GV Grass Valley® Editor Protocols
This setup information applies to the 100/110, 200, and 4000 Editor Protocols.
Cable Connections
The device connects to the switcher over either an RS-422 serial connection to a peripheral port on the frame or a standard ethernet connection.
Acuity™ (Peripheral Port) |
---|
2 (Tx-) |
3 (Rx+) |
7 (Tx+) |
8 (Rx-) |
Switcher Setup
The switcher must be set up to communicate with the editor using either serial or ethernet protocols.
To Set Up Serial Communications
Note: The Editor Remote Enable must be set to on for the editor to control the switcher.
- Press HOME > Setup > Installation > Com Setup
- Press Type and use the Com Port knob to select the peripheral port that you want to set up for the device.
- Use the Device knob to select Editor.
-
Press Select Device and use the Device knob to select the protocol you want to use.
- GVG100/110 — select GVG100
- GVG200 — select GVG200
- GVG4000 — select GVG4000
- Press Com Type and use the Type knob to select RS-422.
- Press Com Settings and use the Baud and Parity knobs to select the communications parameters required by your editor.
-
Press Extra Options and use the Option and Value knobs to set the device
parameters.
Option Value Editor Type (GVG100/110, GVG200) Editware/Sony/Generic Pattern (GVG100/110, GVG200) Pattern # (default) CustCtrl ME (GVG4000) None (default) Bus Mapping (GVG4000) Normal (default) - Press HOME > Confirm.
To Set Up Ethernet Communications
Note: The Editor Remote Enable must be set to on for the editor to control the
switcher.
- Press HOME > Setup > Installation > Com Setup
- Press Type and use the Com Port knob to select the net port that you want to set up for the device.
- Use the Device knob to select Editor.
- Press Select Device and use the Device knob to select Editor.
- Press Com Type and use the Type knob to select Network TCP.
- Press Com Settings and use the Client/Server knob to select the communications parameters required by your editor.
-
Press Extra Options and use the Option and Value knobs to set the device
parameters.
Option Value Editor Type (GVG100/110, GVG200) Editware/Sony/Generic Pattern (GVG100/110, GVG200) Pattern # (default) CustCtrl ME (GVG4000) None (default) Bus Mapping (GVG4000) Normal (default) - Press HOME > Confirm.
Custom Control ME Selection
Memory Number | Custom Control |
---|---|
0-19 | Bank 1: CC 1-20 |
20-39 | Bank 2: CC 1-20 |
40-59 | Bank 3: CC 1-20 |
60-79 | Bank 4: CC 1-20 |
80-99 | Bank 5: CC 1-20 |