To Set Up a Transition Limit
A transition limit is set using the fader of the ME that you want to set up the transition limit on. The transition limit is specific to the ME it is set on.
The transition limit is specific to the MiniME™ it is set on.
- Set up the transition you want to perform.
- Press NEXT until Limit is shown on the menu. Click Navigation Menu > Live Assist > MiniME, select the MiniME™ that you want to perform the transition on, and click Trans.
- Move the fader to the position in the transition where you want to set the transition limit point. Click Trans Limit and use the Limit Position slider to select the position in the transition where you want to set the transition limit point.
-
Toggle the Limit knob (On) to set the transition limit
point.
Click a Trans Limit button to select whether the transition stops at the
transition limit (On), or not (Off).
The segment on the transition progress bar next to the fader handle flashes, indicating the location of the transition limit point.
The transition limit is set and active for the ME you set it on. You can turn transition limit on and off by toggling the Limit knob while the fader is at either the top or bottom limit. If the fader is not on a limit when you toggle the transition limit on, a new transition limit will be set. Double-press the Limit knob to reset the transition limit point.