v11.2.0 Features

64 Aux Buses

The number of aux buses available to the switcher has been increased to 64.

Frame Redundancy

Two switchers can now be set up in a Sender and Listener pair. The Sender is the primary switcher for your production and the Listener is the redundant or backup switcher. Both the Sender and Listener should be configured similarly with the same media assets. When an action is performed on the primary switcher, it sends that command to the redundant switcher. If the primary switcher goes down, the redundant switcher can be used to continue the production.

Note:
The primary and redundant switchers do not have to match exactly. Different switchers can be paired together, but you must remain aware of the resource limitation that this can expose. If the redundant switcher does not have the resources to duplicate the primary switcher, the redundant switcher will use the resources it has.

Multiple Switchers in the Same Frame

MaxConfig can now set up multiple independent HyperMax switchers within the same Ultrix frame. Each switcher must have an SDPE blade assigned as ME P/P. Additional blades can be added or removed from each switcher as required.

Looping Shift

Multiple shift buttons can now be replaced with a single shift button that loops through all the shifted buses. Press the looping shift button repeatedly to go to the next shift bus until coming back to the main bus. The loop progresses through the shift buses in one direction only.

Individual Bus Maps

Bus maps can now be assigned to individual buses separately. This allows you to assign a different map to a keyer bus than the background/preset bus.