Switcher Operation

Event Location Description
Bus Source Copy Switcher > Bus Source Copy Copy the source on the selected bus to another bus.
  1. Click the Source ME button and select the area that you want to copy from.
  2. Click the Source Bus/Keyer button and select the bus that you want to copy from.
  3. Click the Source Bus button and select whether you want to copy the Video (fill) or Alpha of the source.
  4. Click the Destination ME button and select the area that you want to copy to.
  5. Click the Destination Bus/Keyer button and select the bus that you want to copy to.
  6. Click the Destination Bus button and select whether you want to copy to the Video (fill) or Alpha.
Bus Source Select Switcher > Bus Source Select a source on the selected bus for the selected area.
  1. Click the ME button and select the area that you want to select a bus on.
  2. Click the Bus/Keyer button and select the bus that you want to select a source on.
  3. If you selected a key bus, click a Bus button to select whether you are selecting a source for the fill (Video) or the alpha (Alpha) of the key.
  4. Click the Source button and select the source that you want on the selected bus.
ME Copy Switcher > ME Copy Copy the contents of one area to another.
  1. Click the Target ME button and select the location that you want to copy to.
  2. Click the Source ME button and select the location that you want to copy from.
Memory Recall Switcher > Memory Recall > Memory Recall Recall a memory for the selected area.
  1. Click the Include button and select all the locations that you want to perform the memory recall on.
  2. Click the Bank button and select the bank that you want to recall the memory on.
  3. Click the Memory button and select the memory that you want to recall.
Memory Recall Effects Duration Switcher > Memory Recall > Effects Duration Select the duration for the effects dissolve recall.
  1. Click the Effects Duration button for the duration you want to use. Enter a value in the Custom field for a custom duration.
Memory Recall Mode Switcher > Memory Recall > Recall Mode Select the recall mode for the memory recall.
  1. Click the Mode button for the mode you want to use for the memory recall.
Memory Recall Motion Switcher > Memory Recall > Recall Motion Control Select the recall mode for the memory recall.
  1. Click the Motion button and select the effect dissolve motion you want to use.
RState, Load Switcher > Load RState Load the custom reset settings for the selected area.
  1. Click the Include button and select all the locations that you want to recall the custom reset settings on.