The frame comes from the factory set with a static IP address (192.168.0.123) but can be set to use DHCP to automatically obtain an IP address or to a different static IP address. You must connect to the frame from DashBoard to set a different static IP address.

Note: If you use a DHCP server, it must be set to always give the frame the same IP address. DashBoard and the control panel need a fixed IP address to connect to.
Tip: If you do not know the IP address of the frame, you can set DIP switch 3 on the frame to set the IP address to 192.168.0.123. The frame must be re-started for the new IP address to be applied. Remember to set the DIP switch back once you have set the new IP address.

The legacy web-based MediaManager is accessed from a browser directed to the IP address of the switcher frame. You can disable this functionality by turning Disable Web Media Manager to On (Click Navigation Menu > Configuration > System > Global). This does not change the functionality if the MediaManager in DashBoard. The frame must be restarted for the change to be applied.