Tally Port
The switcher supports 34 fixed tallies on a female DB37 connector.
Specification | Value |
---|---|
Input Voltage | 24VAC(rms)/40VDC |
Maximum Current | 120mA |
Impedance | <15 ohm |
For Carbonite eXtreme the tally connectors are on the breakout panel. The center pin of each connector is common (ground).
Note: The tally pin must be connected to the proper common to complete the circuit. For example, tally 6 on pin 7 must be connected to the common on pin 31.
Pin | Tally # |
---|---|
1 | Common (pins 2-6, 20-25) |
2 | 1 |
3 | 2 |
4 | 3 |
5 | 4 |
6 | 5 |
7 | 6 |
8 | 7 |
9 | 8 |
10 | 9 |
11 | 10 |
12 | 11 |
13 | 12 |
14 | 13 |
15 | 14 |
16 | 15 |
17 | 16 |
18 | 17 |
19 | Common (pins 13-18, 32-37) |
20 | 18 |
21 | 19 |
22 | 20 |
23 | 21 |
24 | 22 |
25 | 23 |
26 | 24 |
27 | 25 |
28 | 26 |
29 | 27 |
30 | 28 |
31 | Common (pins 7-12, 26-30) |
32 | 29 |
33 | 30 |
34 | 31 |
35 | 32 |
36 | 33 |
37 | 34 |