Default State
When an ME is reset, or the switcher is restarted, the ME returns to a default state.
- The first source button (Black by default) is selected on the Key, Background, and Preset buses.
- All keys are taken off-air.
- On the Preview Bus module, the PV and the ME buttons for the Program/Preset ME are selected.
- On the Transition modules, Background (BKGD) is selected as included in the next transition, and Dissolve (DISS) is selected as the transition type.
- On the Effects Memory module, the following memories and rates are set unless the Default Transition Rate
personality option is set to on.
- REG:00 — memory register 00 is preset
- Memory00 — memory register 00 was last recalled
- ME:015 — ME transition rate is 15 frames (Interlaced at 59.94 Hz)
- Key:008 — Key transition rate is 8 frames (Interlaced at 59.94 Hz)
- On the Global Memory module, the following memories and rates are set unless the Default Transition Rate
personality option is set to on.
- REG:00 — Memory register 00 is preset
- Memory00 — Memory register 00 was last recalled
- M:015 — ME transition rate is 15 frames (Interlaced at 59.94 Hz)
- D:008 — DSK transition rate is 8 frames (Interlaced at 59.94 Hz)
- F:20 — DSK fade-to-black transition rate is 20 frames (Interlaced at 59.94 Hz)
- Auto Select is selected as the key type in each keyer.
- The Default ME Map is loaded.