To Monitor a Serial Port
-
Navigate to the appropriate menu for the serial port you want to monitor.
- Control Panel Port — Press HOME > More > Diagnostics > Panel Diagnostics > PCH Test > Tx/Rx Test.
- Frame Port — Press HOME > More > Diagnostics > Frame Diagnostics > Tx/Rx Test.
- Use the Com Port knob to select the serial port you want to monitor.
- If you are monitoring a serial port, use the Mode knob to select the transmission standard you want to use for the test.
-
Press Monitor.
Tip: If data is already showing, toggle Freeze to Yes and press Clear.
- Toggle Format to view the data in hexadecimal (Hex) or ASCII (ASCII).
- Toggle View to view the data being sent by the switcher (Tx), or the data being received by the switcher (Rx).
- Toggle Freeze to No to start viewing the data.
-
Save the data to a file by turning Streaming on (Yes) or by pressing
Save.
Note: You cannot save or turn on stream for a communications port that is operating at a baud rate of 115200.
- Streaming — store up to an hour of data
- Save — store just the contents of the screen