To Assign an Aux Bus to a V-053B Auxiliary Control Panel

  1. Press HOME > Setup > Installation > Aux Bus > Remote Panels > Remote Panel Setup.

    This places all the V-053B panels connected to the switcher into programming mode. The On-Air indicators on the panels flash.

  2. Press the source buttons that correspond to the aux buses you want to assign to the auxiliary control panel. Each auxiliary control panel can be assigned to one or all aux buses. Press the button repeatedly to assign a different mode to that aux bus on the panel.
    • Off — the aux bus is not assigned to the auxiliary control panel.
    • On — the aux bus is assigned to the auxiliary control panel, allowing you full control to select sources on the aux bus.
    • Flashing — the aux bus is assigned to the auxiliary control panel, allowing you to only view what is being selected on the aux bus. You will not be able to change the source selections for this aux bus from this auxiliary control panel.

    Starting from the top left, the first 12 source buttons on the control panel correspond to the 12 aux buses that were assigned to the External Link port. For example, if aux buses 1:1 to 2:4 were assigned to the External Link port, button 1 on the auxiliary control panel will assign the panel to aux bus 1:1.

  3. Press Accept.
  4. Press HOME > Confirm.