Default State

When an ME is reset, or the switcher is restarted, the ME returns to a default state.

  • The first source button (Black by default) is selected on the Key, Background, and Preset buses.
  • All keys are taken off-air.
  • On the Preview Bus module, the PV and the ME buttons for the Program/Preset ME are selected.
  • On the Transition modules, Background (BKGD) is selected as included in the next transition, and Dissolve (DISS) is selected as the transition type.
  • On the Effects Memory module, the following memories and rates are set unless the Default Transition Rate personality option is set to on.
    • REG:00 — memory register 00 is preset
    • Memory00 — memory register 00 was last recalled
    • ME:015ME transition rate is 15 frames (Interlaced at 59.94 Hz)
    • Key:008 — Key transition rate is 8 frames (Interlaced at 59.94 Hz)
  • On the Global Memory module, the following memories and rates are set unless the Default Transition Rate personality option is set to on.
    • REG:00 — Memory register 00 is preset
    • Memory00 — Memory register 00 was last recalled
    • M:015ME transition rate is 15 frames (Interlaced at 59.94 Hz)
    • D:008 — DSK transition rate is 8 frames (Interlaced at 59.94 Hz)
    • F:20 — DSK fade-to-black transition rate is 20 frames (Interlaced at 59.94 Hz)
  • Auto Select is selected as the key type in each keyer.
  • The Default ME Map is loaded.