To Set Up a GPI on a V-053B Panel

  1. Press HOME > Setup > Installation > Aux Bus > Remote Panels > Remote Panel Setup.

    This places all the V-053B panels connected to the switcher into programming mode. The On-Air indicators on the panels flash.

  2. Press CLEAN FEED on the V-053B panel.
  3. Press the source button that corresponds to the GPI group you want to assign to the auxiliary control panel.

    Starting from the top left, the first 8 source buttons on the control panel correspond to GPI groups 1 through 8. For example, if an auxiliary control panel is assigned to GPI Group 2, GPIs 9-16 are used.

  4. Press Accept.
  5. Press HOME > Confirm.